Home / Product / Transdermal Diffusion / RT800 Franz Diffusion Cell System

RT800 Franz Diffusion Cell System

RT800 Franz Diffusion Cell System is consisting of Franz diffusion cells and an automatic sampling device. It complies with the European Pharmacopoeia (EP9.0): General rules<2.9.4 Dissolution test for transdermal patches> and the United States Pharmacopoeia: General rules<1724> Semisolid Drug Products – Performance Tests requirements for in vitro release tests (IVRT) and in vitro permeation tests (IVPT). Through automated operations, it can achieve complex cleaning, sampling, and refilling functions to improve the accuracy of test results.

Learn More

Get Free Quote

Download Sheet

icon_video_play
Franz diffusion cell
icon_swiper_prev
icon_swiper_next
  • Complies with regulation USP<1724>
  • 7 channels synchronized automatic sampling
  • Meet audit trail requirements
  • Shorter pipeline design effectively reduces sample residue
  • Description

Features

Compliant diffusion cell style

Compliant diffusion cell style

Compliant with the diffusion cell style recommended by USP<1724>

Shorter pipeline design

Shorter pipeline design

The sampling pipeline is shorter, which can reduce the risk of pipeline residue.

The number of diffusion cell: 6+1

The number of diffusion cell: 6+1

A group can conduct up to 7 diffusion cell tests, so a blank group can be designed to exclude other interference.

Simultaneous sampling design

Simultaneous sampling design.

When sampling, the diffusion pools in the same group will be sampled at the same time to reduce the impact of sampling time on the test results

Two groups independent design

Two groups independent design

The two groups of diffusion cells can be used for testing at the same time without interfering with each other.

Filling point design

Filling point design

The filling point is marked on the diffusion cell. After removing the bubbles, the medium is injected to the filling point to ensure that no bubbles are generated in the future.

Application

Meet the test requirements of USP<1724> for in vitro release and in vitro permeation of semi-solid preparations

  • creams

  • ointments

  • patches

  • gels

img_application

Specifications

Product Brochure

icon_pdf

Automatic Sampling Transdermal Diffusion System


Diffusion cell position: 7×2

Sampling channels: 7

Diffusion cell volume: 10ml, 15ml, 20ml, 25ml, 30ml, 40ml

Sampling times: ≤24

Sampling range: 0.2~1.5ml

Temperature error: ≤±0.5℃

Temperature range: room temperature~45℃

Speed range: 200~900rpm

Speed error: <±10%

Heating method: dry heating

Manual bubble exhaust

Maximum sampling time: 9999mins

Have A Business Inquiry?

Interested to find out more about how our products and services can serve your business needs? Drop us an online inquiry and our qualified professionals will reach out to you.

Get Free Quote