RT600-ST Automated Dissolution Sampling Apparatus
The RT806 is structured as a small-sized Vertical Franz Diffusion Cell system that includes heating functionalities with a built-in stirrer module. The device comes with a portable layout that makes it easy to place in any location for convenient operation. The system delivers detailed temperature and speed management needed for reliable transdermal testing. The system meets the performance requirements outlined in USP<1724> for the simulation of in vitro release and permeation procedures. Bubbles are prevented through the filling point design which results in dependable experimental outcomes.
Learn More
Get Free Quote
Download Sheet
- High Anti-adsorption Pipeline
- High-precision Sampling
- Complete Filtration Solutions
- Optional Online Dilution
-
The device follows USP<1724> specifications to perform in vitro release tests and permeation studies that evaluate creams gels and patches. The instrument design includes a filling point that prevents bubbles from forming which leads to precise and dependable outcomes.
-
The RT600-ST performs automatic preheating functions and incorporates covered dissolving cups that maintain uniform testing conditions. Switching methods with this instrument becomes possible because of its paddle-basket co-axial design that requires no recalibration.
The automatic sample collection system has enhanced efficiency by designing a capacity to handle 120 vials in liquid phase format. Continuous filtration occurs through dual online filters that stop equipment clogs from forming.
Features
Application
Basket and paddle methods are the most commonly used legal dissolution methods in national pharmacopoeias and were the first dissolution methods introduced into pharmacopoeias. They are mainly used for quality control (QC) of pharmaceutical products.
-
Oral Tablets
-
Patch
-
semi-solid preparations
-
Injection
-
Intrinsic Dissolution Rate of API
Specifications
Product Brochure
General Dissolution System
Length ×Width× Height(Fully Raised): 63 cm × 56cm ×96 cm |
Dissolution Vessel Number: 8 |
Setting Range: 20-250 rpm (RPM) |
RPM Resolution: 0.01RPM |
Steady Speed Error: ≤±0.3RPM |
Temp. Accuracy: ≤±0.2℃ |
Temp. Resolution: 0.01 ℃ |
Level: < 0.5° |
Vessel Verticality: 90°±0.5° |
Shaft Verticality: 90°±0.5° |
Centering Deviation: < ±2.0 mm |
Depth Positioning Deviation: < ±1.0 mm |
Shaft Wobble: < ±1.0 mm |
Basket Wobble: < ±1.0 mm |
Automatic Sampling Workstation
Length ×Width× Height: 40 cm ×70cm ×70 cm |
Maximum Settable Sample Number: 20 |
Sampling Range: 1 ~ 20ml |
Minimum Sampling Interval: First Sampling Point: 3 minutes |
Maximum Working Time: 720 hours |
Sampling Precision: ≤±1% |
Operating System
Meeting FDA21 CFR Part 11 |
Have A Business Inquiry?
Interested to find out more about how our products and services can serve your business needs? Drop us an online inquiry and our qualified professionals will reach out to you.
Get Free Quote